History
-------------------------------------------------------------------------------------------
Project:    OH88 2 X DVB-S(2) -> 2 X COFDM Application
-------------------------------------------------------------------------------------------
Key:    + Added           - Removed           * Changed           # Bugfix 
===========================================================================================
Version       Date        Programmer    Changes
-------------------------------------------------------------------------------------------
 V1.53        23.09.2011  B.Hoffmann    # saving of licence time (lost of licence after
                                          power down) fixed 

 V1.51        15.09.2011  B.Hoffmann    + support of HW3 with changed port functions added
                                        + seti command to switch off setting immediate added
                                          (needed for USB config load)

 V1.50        23.08.2011  B.Hoffmann    + ista status readback with new OH50 V1.34 added
                                        + temp correcture offset added* save settings in remote first before settings are done
                                        + function to set descram services if lists in
                                          SmartMPEG and EEPROM are not equal
                                        + turn off of carrier while settings in the modulator
                                          are done (Sumsung ext. NIT problem)
                                        # license testing only if tuner locked
                                        * main menu wrap around

 V1.48        20.06.2011  B.Hoffmann    # tuner manual clock setting in channel B fixed
                                        # external NIT with corrected SDT and PAT

 V1.46        27.05.2011  B.Hoffmann    * new tuner driver implemented
					+ CAM Clk menu for manual clock calc added
					+ CClkOff menu for TS clock data valid gap
                                          determination added
                                        * faster modulator start with no signal
                                        # in remux mode adding of services with same SVID
                                          in channel A and B fixed
                                        + modulator update with new modulator version added
					+ PIDFilter for CAT correction and EEM filter for
                                          decrypted services added
                                        # subsub to sub menu bug fixed
					# menu end bug in channel B fixed

 V1.42        24.02.2011  B.Hoffmann	# determination of used PID filters fixed
                                        * modulator set retry only if service list not empty
                                        * tuner unlock lock modulator refresh only if 
                                          service list not empty
                                        * remote settings optimized
                                        + used PID filters and module ident to status
                                          for remote control added
                                        # set diseqc info at startup added
                                        + CRC function extended to run with old and new 
                                          bootloader
                                        * input LED's yellow while modulator setting
                                        # transparent mode stuffing filter added
                                        # carrier supression while setting of modulator 
                                          (remux channel B active problem)
                                        + external NIT
                                        + NIT license handling
                                        * new CPLD code added (2 * power CAM problem)
                                        # TS handling of tuner fixed to 50% duty cycle (CAM problems)
                                        * output frequency extended to 878 MHz 
                                          (Remux channel 69 problem)

 V1.31        03.12.2010  B.Hoffmann    # CAID handling for decryption corrected

 V1.30        29.11.2010  B.Hoffmann	+ Stuffing status in menu added
                                        # COFDM remux mode fixed
                                        + automatic NIT generation added
                                        + short service names
                                        * label strings for diseq modes improved
                                        + refresh for PID filter and NIT generator if tuner was unlocked

 V1.20        20.09.2010  B.Hoffmann    # PID-Filter select mode function corrected
                                        # PID-Filter transp. mode corrected
                                        # PID-Filter menu length in transp. mode corrected
                                        # OutFreq output with 7 MHz ChOffset corrected
                                        * cursor position in text menus for better readability
 
 V1.10        30.08.2010  B.Hoffmann    # COFDM output level adjusting fixed
                                        # modulator set spectrum function fixed
                                        # modulator get lock info function fixed
                                        * default setting of COFDM PID filter mode is select
                                        * PID-Filter mode string changed from filter to transp.
                                        # qout=2 (auto) works now correct ormal and after reset
                                        # olev function returns now 0 if both channels are off
                                          normal and in auto mode (qout=2)

 V1.00        06.08.2010  B.Hoffmann    first release index A